Optical Line Protection
C-LIGHT Optical Line Protection (OLP) is a critical redundancy solution in optical communication networks, ensuring zero service interruption by monitoring signal strength and quality in real time, coupled with automatic redundant path switching (e.g., 1+1 or 1:N protection architectures). It achieves millisecond-level recovery during fiber cuts, signal degradation, or equipment failures. Core components include optical switches, power detection modules, and intelligent controllers, supporting bidirectional/unidirectional protection modes for long-haul backbones, metro networks, and data center interconnects. Advancements focus on AI-driven dynamic routing optimization, multi-domain coordination (e.g., OTN-OLP synergy), and predictive maintenance to meet ultra-high availability and low-latency demands in 5G, cloud computing, and industrial IoT applications.
  • 3-year warranty Long term maintenance
  • Technical Support Professional free technical guidance
  • 100% detection Each module is 100% tested
  • Spot stock Always in stock, short delivery time
  • Product Details
    OLP Optical Line Protection System

    The OLP optical line protection subsystem launched by C-Light Network communication Co., Ltd.is based on the advanced development of optical switch technology. It’s an automatic monitoring and protection system independent of communication transmission system and completely based on the physical link of optical cable. The system can automatically switch the signal to the optical fiber of the protection path when performance deterioration or blocking of work path is detected. In this way, an optical communication network with high reliability, safety, flexibility and strong disaster resistance is established.

    Product FeatureProduct Diagram

    lApplicable to all kinds of optical communication system

    lSupport line protection of dual fiber and single fiber transmission network

    lSupport multiple working modes of automatic or manual switching

    lSupporting real-time monitoring of main and backup routes

    lFast response: switching time<20ms<>

    lSupport automatic non-return and automatic return functions, automatic return time can be set to adapt to a variety of application scenarios

    lSupport panel button operation. The system can be operated by button on site without management card.

    lOLP card and network management card are independent of each other and have no influence on each other

    CL-OTN-3900 1RU: 442 (W350 (D) ×44 (H)mm

    /CLOLP-xxx-L-1RU

    CLOLP-xxx-L 1RU442 (W250 (D) ×44 (H) mm

    lSupport multi-kinds of gra phical interface network management, such as SNMP, Web

    lSupport power-off and power-on retention functions

    lSupport AC power 220V, DC power -48V, and 1+1 power input protection

    Product Specification

    FunctionParameter
    Working wavelength range1260nm ~ 1650nm
    OLP typeOLP-1:1OLP-1+1OLP-1-1OLP-BIDI
    Switching time<35ms<15ms<15ms<15ms
    Main path loss<4dB<1.3dB<1.3dB<5.5dB
    Backup path loss<1.2dB<1.3dB<1.3dB<5.5dB
    Monitoring power range-50 dBm ~+25dBm
    Working temperature range-10℃~60℃
    Working humidity range5%~95% no condensation
    Storage temperature-40℃~85℃
    Equipment dimension

    CL-OTN-3900 1RU: 442(W)×350(D)×44(H)mm 

    CLOLP-xxx-L1RU:442 (W)×250 (D) ×44 (H)mm 

    Network managementSupport multi-kinds of graphical interface network management, such as SNMP, Web
    Optical interfaceLC/UPC
    Power supplyAC: 90 ~ 260V or DC:  -72~ -36  V (support 1+1 power input backup)
    Typical power consumptionFull configuration<30w
    Heat dissipationFan cooling
    MTBF>100000 hours
    OBP Optical Bypass Protection System
    The OBP optical bypass protection subsystem (Bypass) is an intelligent optical path switching system. It belongs to the physical layer equipment and is applied to pure optical network environment. It can automatically identify the power supply status and optical signal output status of network nodes. When the local optical equipment fails (including power interruption, hardware or software failures), it can instantaneously switch to the bypass optical path, and the communication line will bypass the local equipment (i.e. the fault node), thus avoiding the total resistance obstacle caused by the fault node and ensuring the normal system connectivity.
    FunctionParameter

    lApplicable to all kinds of gateway equipment, such as DPI equipment, firewall, IPS, UTM, IDP, spam gateway, anti-virus gateway, special DDos equipment, special logic isolation equipment in all fields, etc.

    lSupport power-off and power-on retention function: Bypass equipment’s power-off or power-on, does not affect the switching status of work routing to ensure the normal operation, and has hot-swap function.

    lUnique power storage function to ensure that no .wrong switch occurs even when the bypass equipment itself is power off.

    lAutomatic instantaneous switch to fault nodes without human intervention, switching time < 20ms.

    lOBP card and network management card are independent of each other and have no influence on each other

    lSupport multi-kinds of graphical interface network management, such as SNMP, Web

    lSupport AC power 220V, DC power -48V, and 1+1 power input protection

    CL-OTN-2900 1RU442 (W)×280 (D) ×44 (H) mm


    Bypass-Unite
    Product Specification
    FunctionParameter
    Working wavelength range850nm、1260nm ~ 1650nm
    OBP typeOBPA (dual fiber 1+1 protection)OBPB (dual fiber 1:1 protection)
    Switching time<20ms<20ms

    Introduction loss

    Cascade<3.5dB (typical 50%: 50% splitter)<1.5dB
    Bypass<4.5dB (typical 50%: 50% splitter)<1.5dB
    Monitoring power range-50 dBm ~+23dBm
    Working temperature range-10℃~60℃
    Working temperature range5%~95% no condensation
    Storage temperature-40℃~85℃
    Equipment dimensionOSP2900 1RU:442(W)×280 (D) ×44 (H) mm
    Network managementSupport multi-kinds of graphical interface network management, such as SNMP, Web
    Optical interfaceLC/UPC
    Power supplyAC: 90 ~ 260V or DC:  -72~ -36 V(support 1+1 power input backup)
    Typical power consumptionFull configuration<25w<>
    Heat dissipationFan cooling
    MTBF>100000 hours


    Support & Service
    Customization
    C-LIGHT R&D and sales provide various personalized product customization services for customers in d...
    - 01 -
    Quality Assurance
    C-LIGHT ensures good product quality and quality assurance through a series of effective measures.
    - 02 -
    Customer Service
    C-LIGHT provides professional pre-sales and after-sales services, including product certification qu...
    - 03 -
    Production Guarantee
    C-LIGHT provides an excellent production environment to ensure that products can meet customer needs...
    - 04 -
    Performance Testing
    C-LIGHT network tests the performance indicators of optical modules such as eye diagram, optical pow...
    - 05 -
    Reliability Test
    C-LIGHT Network uses professional testing equipment to conduct high and low temperature chamber test...
    - 06 -
    Quality inspection
    ●100% of products pass initial test, final test and factory inspection.

    ●3-step quality control management process.

    ●100% complete implementation of customer order quality requirements.

    ●100% guarantee of customer product data information security.

    Quality certification

    Please contact us to download the certification certificate.

    Quality certification

    Please Note: Installing a third party transceiver does not void your network equipment warranty. Network equipment manufacturers all have guidelines stating that warranty support on their products will not be affected.

    Any question?
    We are here ready for you.
    Copyright © 2011-2025 C-LIGHT.COM INC.
    All Rights Reserved

    Call